Building Categorization Matrix

Building Categorization Matrix

Construction Risks

PLOT RISKS (PR)

 
STRUCTURAL RISKS (SR)

CONSTRUCTION RISK LEVEL

Low: 4 < 8
Medium: 8 < 12
High: 12 < 30
4.0 LOW

Occupant Load Calculation Sheet

Reference: Table 2.6.1. of the National Myanmar Building Code

Occupancy type Floor Area in sq-feet per person Type of area Total area (in sqf) Total number of occupants
1 Accessory storage areas, mechanical ,equipment room Gross
2 Agricultural building Gross
3 Aircraft Hangars Gross
4 Airport Terminal        
4.1 Baggage claim Gross
4.2 Baggage handling Gross
4.3 Concourse Gross
4.4 Waiting areas Gross
5 Assembly, Gaming floors (keno, slots, etc.) Gross
6 Assembly with fixed seats Nr of seats + wheel chair space
7 Assembly without fixed seats      
7.1 Concentrated (chairs only-not fixed) Net
7.2 Standing space Net
7.3 Unconcentrated (tables and chairs) Net
8 Bowling centers Net
9 Business areas (Offices, etc.) Gross
10 Courtrooms-other than fixed seating areas Net
11 Day Care Net
12 Dormitories Gross
13 Educational        
13.1 Classroom area Net
13.2 Shops and other vocational room areas Net
14 Exercise rooms Gross
15 Fabrication and manufacturing areas Gross
16 Industrial areas Gross
17 Instutitional areas        
17.1 Inpatient treatment areas Gross
17.2 Outpatient areas Gross
17.3 Sleeping areas Gross
18 Commercial Kitchen Gross
19 Library        
19.1 Reading rooms Net
19.2 Stack area Gross
19.3 Locker rooms Gross
20 Commercial        
20.1 Areas on other floors Gross
20.2 Basement and grade floor areas Gross
20.3 Storage, stock, shipping areas Gross
21 Parking Garages Gross
22 Residential        
  Total area Grosss
  OR
  Total number master bedroom  
  Total number single bedroom  
  Total number maid bedroom  
23 Skating rinks, swimming pools        
23.1 Rink and pool Gross
23.2 Decks Gross
24 Stages and Platforms Net
25 Warehouses Gross
Maximum Premise Occupancy Rate

Gross floor area of a building, means the total floor area calculated based on a center of exterior walls, including the circulation areas such as stairs, corridors, etc. but excluding the shafts, ducts, lift wells, etc. (MNBC, chapter 2.3.3., Occupancy Load)

Use Risks

Occupancy Capacity

 
Type of Occupancy

Assembly
Type of occupancy % Coefficient Grade of risk (from 1 to 5) Area
Business
Educational
Factories and Industrial
High Hazardous
Institutional
Mercantile
Residential
Storage
Utility and Miscellaneous
 
 
100.0%
OK
USE RISK LEVEL

Low: 2 < 12
Medium: 12 < 40
High: > 40
10.0 Low
 

Definition of the Final Category

  Construction risk level
L M H
Use risk Level L 1 2 2
M 2 2 3
H 3 3 3
BUILDING PERMIT CATEGORY
LOW
 

Documentation to Prepare for the Application

CONSTRUCTION RISK

HIGH
 

USE RISK

LOW
DOCUMENTATION FOR LOW RISK PROJECT TO PRESENT FOR THE BUILDING PERMIT
  • Application form for building permit
  • Power of attorney (if needed)
  • Declaration of responsibility of the applicant
  • Declaration of responsibility from the certified professional in charge of the architectural design
  • Declaration of responsibility signed by the Certified Professional in charge of the construction
  • Copy of the National Registration Card of the applicant (NRC)
  • Copy of the D-Map and grant or evidence of Land Ownership
  • Suggestion letter of the Street and Bridges Task Force (if needed)
  • Architectural drawings
  • Photo report of the existing environment of the projected building
  • Suggestion letter of the Fire Service Department (if building concerned by the section 17 of the Myanmar Fire Force law)
DOCUMENTATION FOR MEDIUM RISK PROJECT TO PRESENT FOR THE APPROVAL IN PRINCIPLE
  • Application form for building permit
  • Power of attorney (if needed)
  • Declaration of responsibility of the applicant
  • Declaration of responsibility from the certified professional in charge of the architectural design
  • Copy of the National Registration Card of the applicant (NRC)
  • Copy of the D-Map and grant or evidence of Land Ownership
  • Suggestion letter of the Street and Bridges Task Force (if needed)
  • Architectural drawings
  • Photo report of the existing environment of the projected building
  • Traffic Impact Assessment (if necessary)
  • Environment Compliance Certificate including the DNI (if necessary)
DOCUMENTATION FOR HIGH RISK PROJECT TO PRESENT FOR THE APPROVAL IN PRINCIPLE
  • Application form for building permit
  • Power of attorney (if needed)
  • Declaration of responsibility of the applicant
  • Declaration of responsibility from the certified professional in charge of the architectural design
  • Copy of the National Registration Card of the applicant (NRC)
  • Copy of the D-Map and grant or evidence of Land Ownership
  • Suggestion letter of the Street and Bridges Task Force (if needed)
  • Architectural drawings
  • Photo report of the existing environment of the projected building
  • Traffic Impact Assessment (if necessary)
  • Environment Compliance Certificate including the DNI (if necessary)

Additional documentation

NO ADDITIONAL DOCUMENTATION REQUIRED
If the low risk project is concerned by the section 17 of the Myanmar Fire Force Law, a suggestion letter will have to be provided

Additional Documentation for Medium risk project to present for the building permit

Administrative Declaration of responsibility signed by the Certified Professional in charge of the structure design
Declaration of responsibility signed by the Certified Professional in charge of the construction
Declaration of responsibility signed by the Certified Professional in charge of the water supply and sanitation
Declaration of responsibility signed by the Certified Professional in charge of the deep excavation design (if needed)
Declaration of responsibility signed by the piling company (if needed)
Theodolite Reading of the adjacent buildings(If the adjacent building is above 3 storey)
Graphical Updated drawings (architecture and structure)
Structural calculations and soil test
Water connection and sanitation designs
Suggestion letter of the Fire Service Department
Approved drawings from the Fire Services Department
Persons with Reduced Mobility (PRM) Study (if needed by the chapt. 2.7. of the MNBC)
 

Do you require a Licensed Contractor (LC) to execute the works ?

YES